The Search Volume Parameter file contains the 24 fields shown in the table. All fields are numeric and are compulsory. The default value for a field is the value used by the process if the field value has been entered as - (absent data).
The following fields are included:
Search Volume Parameters File |
||
Field Name |
Default |
Description |
SRENUM |
|
Search volume reference number |
2 |
Search volume shape (1 = 3D rectangular, 2 = ellipsoid) |
|
SDIST1 |
100 |
Maximum search distance in direction 1 (X) |
SDIST2 |
100 |
Maximum search distance in direction 2 (Y) |
SDIST3 |
100 |
Maximum search distance in direction 3 (Z) |
SANGLE1 |
0 |
First rotation angle for search volume |
SANGLE2 |
0 |
Second rotation angle for search volume |
SANGLE3 |
0 |
Third rotation angle for search volume |
SAXIS1 |
3 |
Axis for first rotation (1 = X, 2 = Y, 3 = Z) |
SAXIS2 |
1 |
Axis for second rotation |
SAXIS3 |
3 |
Axis for third rotation |
MINNUM1 |
1 |
Minimum number of samples for first dynamic search volume |
20 |
Maximum number of samples for first dynamic search volume |
|
SVOLFAC2 |
0 |
Axis multiplying factor for second dynamic search volume |
MINNUM2 |
1 |
Minimum number of samples for second dynamic search volume |
MAXNUM2 |
20 |
Maximum number of samples for second dynamic search volume |
SVOLFAC3 |
0 |
Axis multiplying factor for third dynamic search volume |
MINNUM3 |
1 |
Minimum number of samples for third dynamic search volume |
MAXNUM3 |
20 |
Maximum number of samples for third dynamic search volume |
OCTMETH |
0 |
Octant definition method (0 = do not use, 1 = use octants) |
MINOCT |
2 |
Minimum number of octants to be filled |
MINPEROC |
1 |
Minimum number of samples in an octant |
MAXPEROC |
4 |
Maximum number of samples in an octant |
MAXKEY |
0 |
Maximum number of samples with the same key value within an octant |
Go to the next topic (Dynamic Search Volumes)